Genesis Eco

Electric boilers

The Genesis Eco range of floor standing electric boilers is an excellent option for commercial properties. With outputs from 36 to 504kW and efficiencies up to 99.9%, the boilers can be utilised as the primary heat source or as a secondary heat source when working with heat pumps on a hybrid system. This facilitates improved system efficiencies, reduced capital investment and space requirements, plus flexible system design.

2

2 Year
Warranty*

Modulating heat output

Multiple integrated stainless steel heating elements allow variable output. Depending on the model up to 24 steps of operation can be controlled automatically by the boiler or externally via receipt of a 0-10VDC signal. A limitation on the number of steps to be operational is also possible. Modulating control is especially important on hybrid systems where electric boilers are to work together with other heat sources such as heat pumps on modern low temperature heat networks (LTHNs).

Easy controls

The boiler features an easy-to-use touchscreen control, allowing simple installation and commissioning, as well as straightforward monitoring and servicing. This includes easy access to operational parameters such as power output and operating temperatures - all of which are also accessible via Modbus compatible connection.

  • 3 models - S / M / L

  • Operational history and alarm with
    troubleshooting guide

  • Back-up via USB

  • Circuit breaker as standard

  • Automatic restart in case of power failure

  • Ample space for electrical connections and
    control signals

  • Possibility of Modbus communication via
    integrated internet module

  • Alerts via relay output or BMS

Downloads
Technical Data
Power
S36S50
Max power output kW3650
Steps76
1st stepkW5.28.3
Hydraulic
Maximum water flow rate (ΔT 5°C) l/s1.722.40
Nominal water flow rate (ΔT 10°C) l/s0.861.20
Minimum water flow rate (ΔT 30°C) l/s0.290.40
Water pressure loss (ΔT 5°C) kPa6.06.8
Water pressure loss (ΔT 10°C) kPa5.45.7
Water pressure loss (ΔT 30°C) kPa3.53.6
Water test pressurebar6
Minimum water pressurebar0.25
Maximum water pressurebar3
Safety valve ratingbar3
Pressure switch settingbar2.85
Maximum flow temperature°C100
Overheat stat temperature°C105
Design temperature°C110
Water contentlitres24
Electric
Electrical supply415-3-50
Fuse ratingA6380
CurrentA5272
Controls electrical supply230-1-50
Controls fuse rating16
External controlVDC0-10
Cable connectionmm²95
Other
Weight (empty)kg40
Weight (full)kg64
Protection classIP21

Note: The nominal water flow rate (∆T 10°C) is recommended | Good practice advises that the boiler circulation pump (not supplied with boiler) is installed on the return pipe and be speed controlled in line with the output required of the boiler, in order that the design delta T is maintained. The minimum output of the boiler can be fixed to match the modulation capability of the pump which is usually not as low as the boiler is designed to achieve. The boiler is not able to control the pump speed so the BMS or other should provide the facility.

Power
M72M93M114M135M156
Max power output kW7293114135156
Steps79111315
1st stepkW9
Hydraulic
Maximum water flow rate (ΔT 5°C) l/s3.444.445.466.467.46
Nominal water flow rate (ΔT 10°C) l/s1.722.222.733.233.73
Minimum water flow rate (ΔT 30°C) l/s0.570.740.911.081.24
Water pressure loss (ΔT 5°C) kPa13.414.315.316.618.0
Water pressure loss (ΔT 10°C) kPa12.312.412.512.6
Water pressure loss (ΔT 30°C) kPa12.2
Water test pressurebar6
Minimum water pressurebar0.25
Maximum water pressurebar3
Safety valve ratingbar3
Pressure switch settingbar5.85
Maximum flow temperature°C100
Overheat stat temperature°C105
Design temperature°C110
Water contentlitres110
Electric
Electrical supply415-3-50
Fuse ratingA125160200250
CurrentA104134164195225
Controls electrical supply230-1-50
Controls fuse rating16
External controlVDC0-10
Cable connectionmm²2 x 150
Other
Weight (empty)kg175185
Weight (full)kg285295
Protection classIP21

Note: The nominal water flow rate (∆T 10°C) is recommended | Good practice advises that the boiler circulation pump (not supplied with boiler) is installed on the return pipe and be speed controlled in line with the output required of the boiler, in order that the design delta T is maintained. The minimum output of the boiler can be fixed to match the modulation capability of the pump which is usually not as low as the boiler is designed to achieve. The boiler is not able to control the pump speed so the BMS or other should provide the facility.

Power
M72M93M114M135M156M156
Max power output kW204252315378441504
Steps151215182124
1st stepkW1521
Hydraulic
Maximum water flow rate (ΔT 5°C) l/s9.7612.0615.0818.0821.1024.12
Nominal water flow rate (ΔT 10°C) l/s4.886.037.549.0410.5512.06
Minimum water flow rate (ΔT 30°C) l/s1.632.012.513.013.524.02
Water pressure loss (ΔT 5°C) kPa16.116.316.717.117.518.1
Water pressure loss (ΔT 10°C) kPa15.916.016.216.516.717.0
Water pressure loss (ΔT 30°C) kPa15.715.8
Water test pressurebar9
Minimum water pressurebar0.25
Maximum water pressurebar6
Safety valve ratingbar6
Pressure switch settingbar5.85
Maximum flow temperature°C100
Overheat stat temperature°C105
Design temperature°C110
Water contentlitres372
Electric
Electrical supply415-3-50
Fuse ratingA315400500630800
CurrentA310382477573668763
Controls electrical supply230-1-50
Controls fuse rating16
External controlVDC0-10
Cable connectionmm²2 x 240
Other
Weight (empty)kg380390400405410
Weight (full)kg752762772777782
Protection classIP21

Note: The nominal water flow rate (∆T 10°C) is recommended | Good practice advises that the boiler circulation pump (not supplied with boiler) is installed on the return pipe and be speed controlled in line with the output required of the boiler, in order that the design delta T is maintained. The minimum output of the boiler can be fixed to match the modulation capability of the pump which is usually not as low as the boiler is designed to achieve. The boiler is not able to control the pump speed so the BMS or other should provide the facility.