| Performance |
| Heating capacity / COP (DIN EN 14511-x) | A10/W35 - Partial load | kW / COP | 3.69 / 5.63 | 5.61 / 5.90 |
| A7/W35 - Partial load | kW / COP | 3.45 / 5.04 | 5.48 / 5.68 |
| A7/W55 - Partial load | kW / COP | 3.20 / 3.03 | 4.94 / 3.29 |
| A2/W35 - Partial load | kW / COP | 6.94 / 4.38 | 10.10 / 4.20 |
| A-7/W35 - Partial load | kW / COP | 9.41 / 3.04 | 13.00 / 2.76 |
| A-7/W55 - Partial load | kW / COP | 8.44 / 2.15 | 12.69 / 2.15 |
| Heating capacity (min/max) | A10/W35 | kW | 3.69 / 10.00 | 5.61 / 13.00 |
| A7/W35 | kW | 3.45 / 10.00 | 5.47 / 13.00 |
| A7/W55 | kW | 3.20 / 10.00 | 4.94 / 13.00 |
| A2/W35 | kW | 3.58 / 10.00 | 4.59 / 13.00 |
| A-7/W35 | kW | 3.57 / 9.41 | 4.74 / 13.00 |
| A-7/W55 | kW | 3.31 / 8.44 | 4.26 / 12.69 |
| Cooling capacity / EER | A35/W18 - Partial load | kW | 8.62 / 4.45 | 8.20 / 4.52 |
| A35/W7 - Partial load | kW | 5.94 / 3.16 | 6.95 / 3.10 |
| Cooling capacity (min/max) | A35/W18 | kW | 3.67 / 10.00 | 5.59 / 12.00 |
| A35/W7 | kW | 2.43 / 8.00 | 3.74 / 12.00 |
| DHW heating capacity | kW | 10 | 13 |
| Maximum flow temperature | 35°C & 55°C | A+++ |
| Maximum flow temperature | °C | 78 |
| Air flow rate at max external pressure | m³/h | 4000 |
| Flow rate (pipe dimensioning) | l/h | 1800 | 2300 |
| Minimum volume buffer tank in series / separation buffer tank | litres | 88 |
| Pressure loss at flow rate | at 1800 l/h | bar | 0.16 | 0.14 |
| Maximum allowable operating pressure | bar | 3 |
| Operating limits |
| Heating circuit return/flow (min/max) | Within operating temperatures | °C | 20 / 65 |
| Operating temperature (min/max) | Heating | °C | -22 / 35 |
| Average bivalence temperature (DIN EN 14825) | Low / Medium | °C | -7 / 7 |
| Sound |
| Sound power level (min/night/max) | dB(A) | 45 / 52 / 60 | 46 / 55 / 60 |
| Sound power level (DIN EN 12102-1) | dB(A) | 49 | 46 |
| General |
| Total weight | kg | 170 | 189 |
| Refrigerating circuit maximum allowable operating pressure (high pressure/low pressure) | MPa (g) | 3.15 / 2.1 |
| Refrigerant type / capacity | / kg | R290 / 1.6 | R290 / 1.9 |
| Safety valve — heating circuit response pressure | bar | 3 |
| Electrical |
| Voltage | Heat pump supply | 3~N/PE/400V/50Hz |
| All-pole fuse protection ¹ ² | Compressor only | A | B16 |
| Control voltage fuse protection ² | A | B10 |
| Effective power consumption (DIN EN 14511-x) | A7/W35 — Partial load | kW | 0.68 | 0.97 |
| Electrical consumption | A7/W35 — Partial load | A | 1.21 | 1.67 |
| Power factor | A7/W35 — Partial load | cosφ | 0.99 | 0.97 |
| Effective power consumption ¹ (min/max) | A7/W35 | kW | 0.58 / 2.17 | 0.95 / 2.78 |
| Maximum machine current ¹ | A | 8 | 11.5 |
| Maximum power consumption ¹ | Within operating limits | kW | 6 | 8 |
| IP protection | IP24 |
| Residual current circuit breaker | If required | Type B |
| Luxtronik wall controller |
| Dimensions | H x W x D | mm | 535 x 330 x 166 |
| Weight | kg | 5.3 |